OEM manufacturer Belt Driven Ac Generator - 200KW-315KW LTP314 Series Brushless AC Alternator – Landtop
OEM manufacturer Belt Driven Ac Generator - 200KW-315KW LTP314 Series Brushless AC Alternator – Landtop Detail:
Standard features:
◆The technical performance and mounting dimension of LTP series generators are
international IEC 60034,NEMA MG1-32,ISO8528,CSA C22.2-100,VDE0530 and
national GB755 standards compliant,the quality of prodcts can reach current international standard.
◆Excellent compatibility with drive systems:standard mounting dimensions can be coupled to any
diesel engines from worldwide,many S.A.E flanges and S.A.E drive discs can be easily interchangealble.
◆Easy access for installation and maintenance,including:coupling to engines,connecting for lead
wire,adjustment for AVR,connecting for rectifier,integrating with current transformers.For balanced
rotor with two sealed and quality ball bearing,LTP generators have the featues of little vibration and
low noise.
◆The standard enclosure protection is IP23.
◆And with standard permanent magnet generator excitation system(PMG)
50Hz – 1500rpm CLASS “H” | |||||||||||
RATING | Winding 311/0.8 Power Factor | ||||||||||
Duty/Temp Rise/Ambient T° | Cont./125K/40°C | Standby/150k/40°C | |||||||||
Phase | 3 Phase | 3 Phase | |||||||||
Voltage | Y | 380 | 400 | 415 | 440 | 380 | 400 | 415 | 440 | ||
△ | 220 | 230 | 240 | 220 | 230 | 240 | |||||
YY | 220 | 220 | |||||||||
LTP314S2 | KVA | 250 | 250 | 250 | 250 | 275 | 275 | 275 | 275 | ||
KW | 200 | 200 | 200 | 200 | 220 | 220 | 220 | 220 | |||
LTP314S3 | KVA | 300 | 300 | 300 | 285 | 330 | 330 | 330 | 314 | ||
KW | 240 | 240 | 240 | 228 | 264 | 264 | 264 | 251 | |||
LTP314S4 | KVA | 325 | 325 | 325 | 305 | 358 | 358 | 358 | 336 | ||
KW | 260 | 260 | 260 | 244 | 286 | 286 | 286 | 268 | |||
LTP314S5 | KVA | 350 | 350 | 350 | 325 | 385 | 385 | 385 | 358 | ||
KW | 280 | 280 | 280 | 260 | 308 | 308 | 308 | 286 | |||
LTP314S6 | KVA | 380 | 380 | 380 | 355 | 413 | 413 | 413 | 390 | ||
KW | 304 | 304 | 304 | 284 | 330 | 330 | 330 | 312 | |||
LTP314S7 | KVA | 400 | 400 | 400 | 369 | 440 | 440 | 440 | 406 | ||
KW | 320 | 320 | 320 | 295 | 352 | 352 | 352 | 325 |
60Hz – 1800rpm CLASS “H” | |||||||||||
RATING | Winding 311/0.8 Power Factor | Winding 05 | |||||||||
Duty/Temp Rise/Ambient T° | Cont./125K/40°C | Standby/150k/40°C | Cont./125K/40°C | ||||||||
Phase | 3 Phase | 3 Phase | 1 Phase | ||||||||
Voltage | Y | 416 | 440 | 460 | 480 | 416 | 440 | 460 | 480 | ||
△ | 240 | 240 | |||||||||
YY | 208 | 220 | 230 | 240 | 208 | 220 | 230 | 240 | |||
LTP314S2 | KVA | 300 | 300 | 300 | 300 | 330 | 330 | 330 | 330 | ||
KW | 240 | 240 | 240 | 240 | 264 | 264 | 264 | 264 | |||
LTP314S3 | KVA | 360 | 360 | 360 | 360 | 381 | 381 | 381 | 381 | ||
KW | 288 | 288 | 288 | 288 | 305 | 305 | 305 | 305 | |||
LTP314S4 | KVA | 394 | 394 | 394 | 394 | 433 | 433 | 433 | 433 | ||
KW | 315.2 | 315.2 | 315.2 | 315.2 | 346 | 346 | 346 | 346 | |||
LTP314S5 | KVA | 420 | 420 | 420 | 420 | 462 | 462 | 462 | 462 | ||
KW | 336 | 336 | 336 | 336 | 370 | 370 | 370 | 370 | |||
LTP314S6 | KVA | 456 | 456 | 456 | 456 | 501 | 501 | 501 | 501 | ||
KW | 365 | 365 | 365 | 365 | 401 | 401 | 401 | 401 | |||
LTP314S7 | KVA | 480 | 480 | 480 | 480 | 528 | 528 | 528 | 528 | ||
KW | 384 | 384 | 384 | 384 | 422 | 422 | 422 | 422 |
Frequency/R.P.M | 50Hz-1500rpm | 60Hz-1800rpm | |||||||||
Duty/Ambient T° | Continuous/40°C | Continuous/40°C | |||||||||
Ins.Class/ T° Rise | H/125° K | H/125° K | |||||||||
Load/Phase/P.F. | Full load/3Phase/0.8 | Full load/3Phase/0.8 | |||||||||
Voltage | Y | 380 | 400 | 415 | 440 | 380 | 416 | 440 | 480 | ||
△ | 220 | 230 | 240 | 220 | 240 | ||||||
YY | 220 | 208 | 220 | 240 | |||||||
LTP314S2 | η(%) | 92 | 92.4 | 92.7 | 93.1 | 91.8 | 92.1 | 92.4 | 92.8 | ||
LTP314S3 | η(%) | 92.3 | 92.7 | 93 | 93.4 | 92 | 92.2 | 92.5 | 92.9 | ||
LTP314S4 | η(%) | 93 | 93.3 | 93.5 | 93.8 | 92.5 | 92.8 | 93.1 | 93.5 | ||
LTP314S5 | η(%) | 92.8 | 93.1 | 93.3 | 93.6 | 92.4 | 92.7 | 93 | 93.4 | ||
LTP314S6 | η(%) | 92.6 | 92.9 | 93.2 | 93.5 | 92.4 | 92.6 | 92.9 | 93.4 | ||
LTP314S7 | η(%) | 92.8 | 93 | 93.3 | 93.5 | 92.5 | 92.8 | 93 | 93.5 |
REACTANCE-TIME CONSTANT(s) H CLASS | |||||||
50Hz @ 400V | 314S2 | 314S3 | 314S4 | 314S5 | 314S6 | 314S7 | |
Kcc | SHORT CIRCUIT RATIO | 0.352 | 0.444 | 0.356 | 0.397 | 0.412 | 0.427 |
Xd | DIR. AXIS SYNCHRONOUS | 2.84 | 2.81 | 2.52 | 2.43 | 2.34 | 2.25 |
X’d | DIR. AXIS TRANSIENT | 0.18 | 0.18 | 0.17 | 0.16 | 0.15 | 0.14 |
X”d | DIR. AXIS SUBTRANSIENT | 0.13 | 0.13 | 0.12 | 0.115 | 0.11 | 0.105 |
Xq | QUAD. AXIS REACTANCE | 2.44 | 2.36 | 2.16 | 2.085 | 2.01 | 1.935 |
X”q | QUAD. AXIS SUBTRANSIENT | 0.36 | 0.34 | 0.3 | 0.285 | 0.27 | 0.255 |
X2 | NEGATIVE SEQUENCE | 0.25 | 0.24 | 0.2 | 0.195 | 0.19 | 0.185 |
X0 | ZERO SEQUENCE | 0.09 | 0.09 | 0.08 | 0.08 | 0.08 | 0.08 |
T’d | TRANSIENT TIME CONST | 0.07s | 0.08s | 0.08s | 0.085s | 0.085s | 0.085S |
T”d | SUB-TRANS TIME CONST | 0.018s | 0.019s | 0.019s | 0.020s | 0.020s | 0.020S |
T’do | O.C. FIELD TIME CONST | 1.65s | 1.7s | 1.7s | 1.75s | 1.75s | 1.75S |
Ta | ARMATURE TIME CONST | 0.017s | 0.018s | 0.018s | 0.019s | 0.019s | 0.019S |
60Hz @ 440V | 314S2 | 314S3 | 314S4 | 314S5 | 314S6 | 314S7 | |
Kcc | SHORT CIRCUIT RATIO | 0.29 | 0.305 | 0.325 | 0.332 | 0.339 | 0.347 |
Xd | DIR. AXIS SYNCHRONOUS | 3.45 | 2.28 | 3.08 | 3.015 | 2.95 | 2.885 |
X’d | DIR. AXIS TRANSIENT | 0.15 | 0.14 | 0.13 | 0.125 | 0.12 | 0.115 |
X”d | DIR. AXIS SUBTRANSIENT | 2.98 | 2.8 | 2.59 | 2.6 | 2.61 | 2.62 |
Xq | QUAD. AXIS REACTANCE | 2.44 | 2.36 | 2.16 | 2.085 | 2.01 | 1.935 |
X”q | QUAD. AXIS SUBTRANSIENT | 0.4 | 0.37 | 0.36 | 0.375 | 0.39 | 0.405 |
X2 | NEGATIVE SEQUENCE | 0.28 | 0.26 | 0.25 | 0.255 | 0.26 | 0.265 |
X0 | ZERO SEQUENCE | 0.09 | 0.09 | 0.09 | 0.09 | 0.09 | 0.09 |
T’d | TRANSIENT TIME CONST | 0.07s | 0.08s | 0.08s | 0.085s | 0.085s | 0.085s |
T”d | SUB-TRANS TIME CONST | 0.018s | 0.019s | 0.019s | 0.020s | 0.020s | 0.020s |
T’do | O.C. FIELD TIME CONST | 1.65s | 1.7s | 1.7s | 1.75s | 1.75s | 1.75s |
Ta | ARMATURE TIME CONST | 0.017s | 0.0018s | 0.018s | 0.019s | 0.019s | 0.019s |
MOMENT OF INERTIA(1-BRG).kgm | 3.553 | 4.077 | 4.633 | 4.995 | 5.429 | 5.921 |
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developments, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Product detail pictures:
Related Product Guide:
Our commission is always to provide our customers and clientele with best quality and aggressive portable digital products for OEM manufacturer Belt Driven Ac Generator - 200KW-315KW LTP314 Series Brushless AC Alternator – Landtop , The product will supply to all over the world, such as: Spain, Algeria, Egypt, Selling our products causes no risks and brings high returns to your company instead. It is our consistent pursuit to create value for clients. Our company is looking for agents sincerely. What are you waiting for? Come and join us. Now or never.
By Belinda from Riyadh - 2018.12.05 13:53
Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
By Bella from Melbourne - 2017.11.11 11:41