OEM Customized Stamford Generator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop
OEM Customized Stamford Generator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop Detail:
◆The technical performance and mounting dimension of LTP series generators are
international IEC 60034,NEMA MG1-32,ISO8528,CSA C22.2-100,VDE0530 and
national GB755 standards compliant,the quality of prodcts can reach current international standard.
◆Excellent compatibility with drive systems:standard mounting dimensions can be coupled to any
diesel engines from worldwide,many S.A.E flanges and S.A.E drive discs can be easily interchangealble.
◆Easy access for installation and maintenance,including:coupling to engines,connecting for lead
wire,adjustment for AVR,connecting for rectifier,integrating with current transformers.For balanced
rotor with two sealed and quality ball bearing,LTP generators have the featues of little vibration and
low noise.
◆The standard enclosure protection is IP23.
50Hz – 1500rpm CLASS “H” | |||||||||||
RATING | Winding 311/0.8 Power Factor | Winding 05 | |||||||||
Duty/Temp Rise/Ambient T° | Cont./125K/40°C | Standby/150k/40°C | Cont./125K/40°C | ||||||||
Phase | 3 Phase | 3 Phase | 1 Phase | ||||||||
Voltage | Y | 380 | 400 | 415 | 400 | 380 | 400 | 415 | 400 | 220/230/240 | |
△ | 220 | 230 | 240 | 220 | 230 | 240 | Power Factor | ||||
YY | 220 | 220 | 0.8 | 1 | |||||||
LTP184S1 | KVA | 22.5 | 22.5 | 22.5 | 22.5 | 25 | 25 | 25 | 25 | 18 | 18 |
KW | 18 | 18 | 18 | 18 | 20 | 20 | 20 | 20 | 14.4 | 18 | |
LTP184S2 | KVA | 27.5 | 27.5 | 27.5 | 27.5 | 31 | 31 | 31 | 31 | 22 | 22 |
KW | 22 | 22 | 22 | 22 | 24.8 | 24.8 | 24.8 | 24.8 | 17.6 | 22 | |
LTP184S3 | KVA | 31.25 | 31.25 | 31.25 | 31.25 | 35 | 35 | 35 | 35 | 25 | 25 |
KW | 25 | 25 | 25 | 25 | 28 | 28 | 28 | 28 | 20 | 25 | |
LTP184S4 | KVA | 37.5 | 37.5 | 37.5 | 37.5 | 41.25 | 41.25 | 41.25 | 41.25 | 37.5 | 30 |
KW | 30 | 30 | 30 | 30 | 33 | 33 | 33 | 33 | 30 | 30 | |
LTP184S5 | KVA | 40 | 40 | 40 | 40 | 43.75 | 43.75 | 43.75 | 43.75 | 40 | 32 |
KW | 32 | 32 | 32 | 32 | 35 | 35 | 35 | 35 | 32 | 32 |
60Hz – 1800rpm CLASS “H” | |||||||||||
RATING | Winding 311/0.8 Power Factor | Winding 05 | |||||||||
Duty/Temp Rise/Ambient T° | Cont./125K/40°C | Standby/150k/40°C | Cont./125K/40°C | ||||||||
Phase | 3 Phase | 3 Phase | 1 Phase | ||||||||
Voltage | Y | 416 | 440 | 460 | 480 | 416 | 440 | 460 | 480 | 220/230/240 | |
△ | 240 | 240 | Power Factor | ||||||||
YY | 208 | 220 | 230 | 240 | 208 | 220 | 230 | 240 | 0.8 | 1 | |
LTP184S1 | KVA | 27 | 27 | 27 | 27 | 30 | 30 | 30 | 30 | 21.6 | 21.6 |
KW | 21.6 | 21.6 | 21.6 | 21.6 | 24 | 24 | 24 | 24 | 17.3 | 21.6 | |
LTP184S2 | KVA | 33 | 33 | 33 | 33 | 37.2 | 37.2 | 37.2 | 37.2 | 26.4 | 26.4 |
KW | 26.4 | 26.4 | 26.4 | 26.4 | 29 | 29 | 29 | 29 | 21.1 | 26.4 | |
LTP184S3 | KVA | 37.5 | 37.5 | 37.5 | 37.5 | 42 | 42 | 42 | 42 | 30 | 30 |
KW | 30 | 30 | 30 | 30 | 33.6 | 33.6 | 33.6 | 33.6 | 24 | 30 | |
LTP184S4 | KVA | 45 | 45 | 45 | 45 | 49.5 | 49.5 | 49.5 | 49.5 | 36 | 36 |
KW | 36 | 36 | 36 | 36 | 39.6 | 39.6 | 39.6 | 39.6 | 28.8 | 36 | |
LTP184S5 | KVA | 48 | 48 | 48 | 48 | 52.5 | 52.5 | 52.5 | 52.5 | 38.4 | 38.4 |
KW | 38.4 | 38.4 | 38.4 | 38.4 | 42 | 42 | 42 | 42 | 30.7 | 38.4 |
Frequency/R.P.M | 50Hz-1500rpm | 60Hz-1800rpm | |||||||||
Duty/Ambient T° | Continuous/40°C | Continuous/40°C | |||||||||
Ins.Class/ T° Rise | H/125° K | H/125° K | |||||||||
Load/Phase/P.F. | Full load/3Phase/0.8 | Full load/3Phase/0.8 | |||||||||
Voltage | Y | 380 | 400 | 415 | 400 | 380 | 416 | 440 | 480 | ||
△ | 220 | 230 | 240 | 220 | 240 | 200 | |||||
YY | 220 | 208 | 240 | ||||||||
LTP184S1 | η(%) | 84.3 | 84.9 | 85.3 | 85.6 | 83.1 | 83.8 | 84.3 | 85.2 | ||
LTP184S2 | η(%) | 85.7 | 86.2 | 86.5 | 87 | 84.8 | 85.5 | 85.9 | 86.7 | ||
LTP184S3 | η(%) | 85.8 | 86.4 | 86.7 | 87.2 | 85 | 85.7 | 86.1 | 86.8 | ||
LTP184S4 | η(%) | 86.2 | 86.6 | 86.9 | 87.2 | 85.3 | 86 | 86.4 | 87 | ||
LTP184S5 | η(%) | 86.3 | 86.6 | 87 | 87.3 | 85.4 | 86.2 | 86.5 | 87.2 |
REACTANCE-TIME CONSTANT(s) H CLASS | ||||||
50Hz @ 400V | 184S1 | 184S2 | 184S3 | 184S4 | 184S5 | |
Kcc | SHORT CIRCUIT RATIO | 0.592 | 0.606 | 0.641 | 0.500 | 0.488 |
Xd | DIR. AXIS SYNCHRONOUS | 1.69 | 1.650 | 1.560 | 2.000 | 2.051 |
X’d | DIR. AXIS TRANSIENT | 0.175 | 0.165 | 0.150 | 0.152 | 0.156 |
X”d | DIR. AXIS SUBTRANSIENT | 0.12 | 0.113 | 0.110 | 0.083 | 0.085 |
Xq | QUAD. AXIS REACTANCE | 0.84 | 0.830 | 0.780 | 0.967 | 0.990 |
X”q | QUAD. AXIS SUBTRANSIENT | 0.19 | 0.191 | 0.170 | 0.169 | 0.173 |
X2 | NEGATIVE SEQUENCE | 0.16 | 0.150 | 0.140 | 0.127 | 0.130 |
X0 | ZERO SEQUENCE | 0.073 | 0.072 | 0.067 | 0.030 | 0.032 |
T’d | TRANSIENT TIME CONST. | 0.020s | 0.022s | 0.024s | 0.024s | 0.025s |
T”d | SUB-TRANS TIME CONST. | 0.005s | 0.0055s | 0.006s | 0.015s | 0.016s |
T’do | O.C. FIELD TIME CONST. | 0.4s | 0.45s | 0.55s | 0.57s | 0.59s |
Ta | ARMATURE TIME CONST. | 0.006s | 0.0065s | 0.007s | 0.01s | 0.0105s |
60Hz @ 440V | 184S1 | 184S2 | 184S3 | 184S4 | 184S5 | |
Kcc | SHORT CIRCUIT RATIO | 0.466 | 0.489 | 0.539 | 0.420 | 0.435 |
Xd | DIR. AXIS SYNCHRONOUS | 2.148 | 2.047 | 1.857 | 2.380 | 2.297 |
X’d | DIR. AXIS TRANSIENT | 0.217 | 0.199 | 0.190 | 0.181 | 0.175 |
X”d | DIR. AXIS SUBTRANSIENT | 0.137 | 0.140 | 0.119 | 0.099 | 0.095 |
Xq | QUAD. AXIS REACTANCE | 1.063 | 1.029 | 0.916 | 1.151 | 1.109 |
X”q | QUAD. AXIS SUBTRANSIENT | 0.24 | 0.234 | 0.202 | 0.201 | 0.194 |
X2 | NEGATIVE SEQUENCE | 0.194 | 0.187 | 0.179 | 0.151 | 0.145 |
X0 | ZERO SEQUENCE | 0.093 | 0.089 | 0.080 | 0.036 | 0.036 |
T’d | TRANSIENT TIME CONST. | 0.02s | 0.022s | 0.024s | 0.024s | 0.025s |
T”d | SUB-TRANS TIME CONST. | 0.005s | 0.0055s | 0.006s | 0.015s | 0.016s |
T’do | O.C. FIELD TIME CONST. | 0.40s | 0.45s | 0.55s | 0.57s | 0.59s |
Ta | ARMATURE TIME CONST. | 0.006s | 0.0065s | 0.007s | 0.010s | 0.0105s |
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developments, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
OVERALL AND MOUNTING DIMENSIONS
Product detail pictures:
Related Product Guide:
We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for OEM Customized Stamford Generator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop , The product will supply to all over the world, such as: Ecuador, US, Kazakhstan, Our items are exported worldwide. Our customers are always satisfied with our reliable quality, customer-oriented services and competitive prices. Our mission is "to continue to earn your loyalty by dedicating our efforts to the constant improvement of our merchandise and services in order to ensure the satisfaction of our end-users, customers, employees, suppliers and the worldwide communities in which we cooperate".
By Sara from Mauritius - 2017.10.13 10:47
The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
By Marjorie from Slovenia - 2018.06.28 19:27