Manufactur standard Ac Tachometer Generator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop
Manufactur standard Ac Tachometer Generator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop Detail:
◆The technical performance and mounting dimension of LTP series generators are
international IEC 60034,NEMA MG1-32,ISO8528,CSA C22.2-100,VDE0530 and
national GB755 standards compliant,the quality of prodcts can reach current international standard.
◆Excellent compatibility with drive systems:standard mounting dimensions can be coupled to any
diesel engines from worldwide,many S.A.E flanges and S.A.E drive discs can be easily interchangealble.
◆Easy access for installation and maintenance,including:coupling to engines,connecting for lead
wire,adjustment for AVR,connecting for rectifier,integrating with current transformers.For balanced
rotor with two sealed and quality ball bearing,LTP generators have the featues of little vibration and
low noise.
◆The standard enclosure protection is IP23.
50Hz – 1500rpm CLASS “H” | |||||||||||
RATING | Winding 311/0.8 Power Factor | Winding 05 | |||||||||
Duty/Temp Rise/Ambient T° | Cont./125K/40°C | Standby/150k/40°C | Cont./125K/40°C | ||||||||
Phase | 3 Phase | 3 Phase | 1 Phase | ||||||||
Voltage | Y | 380 | 400 | 415 | 400 | 380 | 400 | 415 | 400 | 220/230/240 | |
△ | 220 | 230 | 240 | 220 | 230 | 240 | Power Factor | ||||
YY | 220 | 220 | 0.8 | 1 | |||||||
LTP184S1 | KVA | 22.5 | 22.5 | 22.5 | 22.5 | 25 | 25 | 25 | 25 | 18 | 18 |
KW | 18 | 18 | 18 | 18 | 20 | 20 | 20 | 20 | 14.4 | 18 | |
LTP184S2 | KVA | 27.5 | 27.5 | 27.5 | 27.5 | 31 | 31 | 31 | 31 | 22 | 22 |
KW | 22 | 22 | 22 | 22 | 24.8 | 24.8 | 24.8 | 24.8 | 17.6 | 22 | |
LTP184S3 | KVA | 31.25 | 31.25 | 31.25 | 31.25 | 35 | 35 | 35 | 35 | 25 | 25 |
KW | 25 | 25 | 25 | 25 | 28 | 28 | 28 | 28 | 20 | 25 | |
LTP184S4 | KVA | 37.5 | 37.5 | 37.5 | 37.5 | 41.25 | 41.25 | 41.25 | 41.25 | 37.5 | 30 |
KW | 30 | 30 | 30 | 30 | 33 | 33 | 33 | 33 | 30 | 30 | |
LTP184S5 | KVA | 40 | 40 | 40 | 40 | 43.75 | 43.75 | 43.75 | 43.75 | 40 | 32 |
KW | 32 | 32 | 32 | 32 | 35 | 35 | 35 | 35 | 32 | 32 |
60Hz – 1800rpm CLASS “H” | |||||||||||
RATING | Winding 311/0.8 Power Factor | Winding 05 | |||||||||
Duty/Temp Rise/Ambient T° | Cont./125K/40°C | Standby/150k/40°C | Cont./125K/40°C | ||||||||
Phase | 3 Phase | 3 Phase | 1 Phase | ||||||||
Voltage | Y | 416 | 440 | 460 | 480 | 416 | 440 | 460 | 480 | 220/230/240 | |
△ | 240 | 240 | Power Factor | ||||||||
YY | 208 | 220 | 230 | 240 | 208 | 220 | 230 | 240 | 0.8 | 1 | |
LTP184S1 | KVA | 27 | 27 | 27 | 27 | 30 | 30 | 30 | 30 | 21.6 | 21.6 |
KW | 21.6 | 21.6 | 21.6 | 21.6 | 24 | 24 | 24 | 24 | 17.3 | 21.6 | |
LTP184S2 | KVA | 33 | 33 | 33 | 33 | 37.2 | 37.2 | 37.2 | 37.2 | 26.4 | 26.4 |
KW | 26.4 | 26.4 | 26.4 | 26.4 | 29 | 29 | 29 | 29 | 21.1 | 26.4 | |
LTP184S3 | KVA | 37.5 | 37.5 | 37.5 | 37.5 | 42 | 42 | 42 | 42 | 30 | 30 |
KW | 30 | 30 | 30 | 30 | 33.6 | 33.6 | 33.6 | 33.6 | 24 | 30 | |
LTP184S4 | KVA | 45 | 45 | 45 | 45 | 49.5 | 49.5 | 49.5 | 49.5 | 36 | 36 |
KW | 36 | 36 | 36 | 36 | 39.6 | 39.6 | 39.6 | 39.6 | 28.8 | 36 | |
LTP184S5 | KVA | 48 | 48 | 48 | 48 | 52.5 | 52.5 | 52.5 | 52.5 | 38.4 | 38.4 |
KW | 38.4 | 38.4 | 38.4 | 38.4 | 42 | 42 | 42 | 42 | 30.7 | 38.4 |
Frequency/R.P.M | 50Hz-1500rpm | 60Hz-1800rpm | |||||||||
Duty/Ambient T° | Continuous/40°C | Continuous/40°C | |||||||||
Ins.Class/ T° Rise | H/125° K | H/125° K | |||||||||
Load/Phase/P.F. | Full load/3Phase/0.8 | Full load/3Phase/0.8 | |||||||||
Voltage | Y | 380 | 400 | 415 | 400 | 380 | 416 | 440 | 480 | ||
△ | 220 | 230 | 240 | 220 | 240 | 200 | |||||
YY | 220 | 208 | 240 | ||||||||
LTP184S1 | η(%) | 84.3 | 84.9 | 85.3 | 85.6 | 83.1 | 83.8 | 84.3 | 85.2 | ||
LTP184S2 | η(%) | 85.7 | 86.2 | 86.5 | 87 | 84.8 | 85.5 | 85.9 | 86.7 | ||
LTP184S3 | η(%) | 85.8 | 86.4 | 86.7 | 87.2 | 85 | 85.7 | 86.1 | 86.8 | ||
LTP184S4 | η(%) | 86.2 | 86.6 | 86.9 | 87.2 | 85.3 | 86 | 86.4 | 87 | ||
LTP184S5 | η(%) | 86.3 | 86.6 | 87 | 87.3 | 85.4 | 86.2 | 86.5 | 87.2 |
REACTANCE-TIME CONSTANT(s) H CLASS | ||||||
50Hz @ 400V | 184S1 | 184S2 | 184S3 | 184S4 | 184S5 | |
Kcc | SHORT CIRCUIT RATIO | 0.592 | 0.606 | 0.641 | 0.500 | 0.488 |
Xd | DIR. AXIS SYNCHRONOUS | 1.69 | 1.650 | 1.560 | 2.000 | 2.051 |
X’d | DIR. AXIS TRANSIENT | 0.175 | 0.165 | 0.150 | 0.152 | 0.156 |
X”d | DIR. AXIS SUBTRANSIENT | 0.12 | 0.113 | 0.110 | 0.083 | 0.085 |
Xq | QUAD. AXIS REACTANCE | 0.84 | 0.830 | 0.780 | 0.967 | 0.990 |
X”q | QUAD. AXIS SUBTRANSIENT | 0.19 | 0.191 | 0.170 | 0.169 | 0.173 |
X2 | NEGATIVE SEQUENCE | 0.16 | 0.150 | 0.140 | 0.127 | 0.130 |
X0 | ZERO SEQUENCE | 0.073 | 0.072 | 0.067 | 0.030 | 0.032 |
T’d | TRANSIENT TIME CONST. | 0.020s | 0.022s | 0.024s | 0.024s | 0.025s |
T”d | SUB-TRANS TIME CONST. | 0.005s | 0.0055s | 0.006s | 0.015s | 0.016s |
T’do | O.C. FIELD TIME CONST. | 0.4s | 0.45s | 0.55s | 0.57s | 0.59s |
Ta | ARMATURE TIME CONST. | 0.006s | 0.0065s | 0.007s | 0.01s | 0.0105s |
60Hz @ 440V | 184S1 | 184S2 | 184S3 | 184S4 | 184S5 | |
Kcc | SHORT CIRCUIT RATIO | 0.466 | 0.489 | 0.539 | 0.420 | 0.435 |
Xd | DIR. AXIS SYNCHRONOUS | 2.148 | 2.047 | 1.857 | 2.380 | 2.297 |
X’d | DIR. AXIS TRANSIENT | 0.217 | 0.199 | 0.190 | 0.181 | 0.175 |
X”d | DIR. AXIS SUBTRANSIENT | 0.137 | 0.140 | 0.119 | 0.099 | 0.095 |
Xq | QUAD. AXIS REACTANCE | 1.063 | 1.029 | 0.916 | 1.151 | 1.109 |
X”q | QUAD. AXIS SUBTRANSIENT | 0.24 | 0.234 | 0.202 | 0.201 | 0.194 |
X2 | NEGATIVE SEQUENCE | 0.194 | 0.187 | 0.179 | 0.151 | 0.145 |
X0 | ZERO SEQUENCE | 0.093 | 0.089 | 0.080 | 0.036 | 0.036 |
T’d | TRANSIENT TIME CONST. | 0.02s | 0.022s | 0.024s | 0.024s | 0.025s |
T”d | SUB-TRANS TIME CONST. | 0.005s | 0.0055s | 0.006s | 0.015s | 0.016s |
T’do | O.C. FIELD TIME CONST. | 0.40s | 0.45s | 0.55s | 0.57s | 0.59s |
Ta | ARMATURE TIME CONST. | 0.006s | 0.0065s | 0.007s | 0.010s | 0.0105s |
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developments, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
OVERALL AND MOUNTING DIMENSIONS
Product detail pictures:
Related Product Guide:
We have probably the most state-of-the-art output equipment, experienced and qualified engineers and workers, recognized good quality manage systems plus a friendly skilled income workforce pre/after-sales support for Manufactur standard Ac Tachometer Generator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop , The product will supply to all over the world, such as: Nairobi, Sudan, Macedonia, We adhere to client 1st, top quality 1st, continuous improvement, mutual advantage and win-win principles. When cooperation together with the customer, we provide shoppers with the highest high-quality of service. Established good business relations using the Zimbabwe buyer inside the business, we've got established own brand and reputation. At the identical time, wholeheartedly welcome new and old prospects to our company to go to and negotiate small business.