China OEM 240v Ac Alternator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop
China OEM 240v Ac Alternator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop Detail:
◆The technical performance and mounting dimension of LTP series generators are
international IEC 60034,NEMA MG1-32,ISO8528,CSA C22.2-100,VDE0530 and
national GB755 standards compliant,the quality of prodcts can reach current international standard.
◆Excellent compatibility with drive systems:standard mounting dimensions can be coupled to any
diesel engines from worldwide,many S.A.E flanges and S.A.E drive discs can be easily interchangealble.
◆Easy access for installation and maintenance,including:coupling to engines,connecting for lead
wire,adjustment for AVR,connecting for rectifier,integrating with current transformers.For balanced
rotor with two sealed and quality ball bearing,LTP generators have the featues of little vibration and
low noise.
◆The standard enclosure protection is IP23.
50Hz – 1500rpm CLASS “H” | |||||||||||
RATING | Winding 311/0.8 Power Factor | Winding 05 | |||||||||
Duty/Temp Rise/Ambient T° | Cont./125K/40°C | Standby/150k/40°C | Cont./125K/40°C | ||||||||
Phase | 3 Phase | 3 Phase | 1 Phase | ||||||||
Voltage | Y | 380 | 400 | 415 | 400 | 380 | 400 | 415 | 400 | 220/230/240 | |
△ | 220 | 230 | 240 | 220 | 230 | 240 | Power Factor | ||||
YY | 220 | 220 | 0.8 | 1 | |||||||
LTP184S1 | KVA | 22.5 | 22.5 | 22.5 | 22.5 | 25 | 25 | 25 | 25 | 18 | 18 |
KW | 18 | 18 | 18 | 18 | 20 | 20 | 20 | 20 | 14.4 | 18 | |
LTP184S2 | KVA | 27.5 | 27.5 | 27.5 | 27.5 | 31 | 31 | 31 | 31 | 22 | 22 |
KW | 22 | 22 | 22 | 22 | 24.8 | 24.8 | 24.8 | 24.8 | 17.6 | 22 | |
LTP184S3 | KVA | 31.25 | 31.25 | 31.25 | 31.25 | 35 | 35 | 35 | 35 | 25 | 25 |
KW | 25 | 25 | 25 | 25 | 28 | 28 | 28 | 28 | 20 | 25 | |
LTP184S4 | KVA | 37.5 | 37.5 | 37.5 | 37.5 | 41.25 | 41.25 | 41.25 | 41.25 | 37.5 | 30 |
KW | 30 | 30 | 30 | 30 | 33 | 33 | 33 | 33 | 30 | 30 | |
LTP184S5 | KVA | 40 | 40 | 40 | 40 | 43.75 | 43.75 | 43.75 | 43.75 | 40 | 32 |
KW | 32 | 32 | 32 | 32 | 35 | 35 | 35 | 35 | 32 | 32 |
60Hz – 1800rpm CLASS “H” | |||||||||||
RATING | Winding 311/0.8 Power Factor | Winding 05 | |||||||||
Duty/Temp Rise/Ambient T° | Cont./125K/40°C | Standby/150k/40°C | Cont./125K/40°C | ||||||||
Phase | 3 Phase | 3 Phase | 1 Phase | ||||||||
Voltage | Y | 416 | 440 | 460 | 480 | 416 | 440 | 460 | 480 | 220/230/240 | |
△ | 240 | 240 | Power Factor | ||||||||
YY | 208 | 220 | 230 | 240 | 208 | 220 | 230 | 240 | 0.8 | 1 | |
LTP184S1 | KVA | 27 | 27 | 27 | 27 | 30 | 30 | 30 | 30 | 21.6 | 21.6 |
KW | 21.6 | 21.6 | 21.6 | 21.6 | 24 | 24 | 24 | 24 | 17.3 | 21.6 | |
LTP184S2 | KVA | 33 | 33 | 33 | 33 | 37.2 | 37.2 | 37.2 | 37.2 | 26.4 | 26.4 |
KW | 26.4 | 26.4 | 26.4 | 26.4 | 29 | 29 | 29 | 29 | 21.1 | 26.4 | |
LTP184S3 | KVA | 37.5 | 37.5 | 37.5 | 37.5 | 42 | 42 | 42 | 42 | 30 | 30 |
KW | 30 | 30 | 30 | 30 | 33.6 | 33.6 | 33.6 | 33.6 | 24 | 30 | |
LTP184S4 | KVA | 45 | 45 | 45 | 45 | 49.5 | 49.5 | 49.5 | 49.5 | 36 | 36 |
KW | 36 | 36 | 36 | 36 | 39.6 | 39.6 | 39.6 | 39.6 | 28.8 | 36 | |
LTP184S5 | KVA | 48 | 48 | 48 | 48 | 52.5 | 52.5 | 52.5 | 52.5 | 38.4 | 38.4 |
KW | 38.4 | 38.4 | 38.4 | 38.4 | 42 | 42 | 42 | 42 | 30.7 | 38.4 |
Frequency/R.P.M | 50Hz-1500rpm | 60Hz-1800rpm | |||||||||
Duty/Ambient T° | Continuous/40°C | Continuous/40°C | |||||||||
Ins.Class/ T° Rise | H/125° K | H/125° K | |||||||||
Load/Phase/P.F. | Full load/3Phase/0.8 | Full load/3Phase/0.8 | |||||||||
Voltage | Y | 380 | 400 | 415 | 400 | 380 | 416 | 440 | 480 | ||
△ | 220 | 230 | 240 | 220 | 240 | 200 | |||||
YY | 220 | 208 | 240 | ||||||||
LTP184S1 | η(%) | 84.3 | 84.9 | 85.3 | 85.6 | 83.1 | 83.8 | 84.3 | 85.2 | ||
LTP184S2 | η(%) | 85.7 | 86.2 | 86.5 | 87 | 84.8 | 85.5 | 85.9 | 86.7 | ||
LTP184S3 | η(%) | 85.8 | 86.4 | 86.7 | 87.2 | 85 | 85.7 | 86.1 | 86.8 | ||
LTP184S4 | η(%) | 86.2 | 86.6 | 86.9 | 87.2 | 85.3 | 86 | 86.4 | 87 | ||
LTP184S5 | η(%) | 86.3 | 86.6 | 87 | 87.3 | 85.4 | 86.2 | 86.5 | 87.2 |
REACTANCE-TIME CONSTANT(s) H CLASS | ||||||
50Hz @ 400V | 184S1 | 184S2 | 184S3 | 184S4 | 184S5 | |
Kcc | SHORT CIRCUIT RATIO | 0.592 | 0.606 | 0.641 | 0.500 | 0.488 |
Xd | DIR. AXIS SYNCHRONOUS | 1.69 | 1.650 | 1.560 | 2.000 | 2.051 |
X’d | DIR. AXIS TRANSIENT | 0.175 | 0.165 | 0.150 | 0.152 | 0.156 |
X”d | DIR. AXIS SUBTRANSIENT | 0.12 | 0.113 | 0.110 | 0.083 | 0.085 |
Xq | QUAD. AXIS REACTANCE | 0.84 | 0.830 | 0.780 | 0.967 | 0.990 |
X”q | QUAD. AXIS SUBTRANSIENT | 0.19 | 0.191 | 0.170 | 0.169 | 0.173 |
X2 | NEGATIVE SEQUENCE | 0.16 | 0.150 | 0.140 | 0.127 | 0.130 |
X0 | ZERO SEQUENCE | 0.073 | 0.072 | 0.067 | 0.030 | 0.032 |
T’d | TRANSIENT TIME CONST. | 0.020s | 0.022s | 0.024s | 0.024s | 0.025s |
T”d | SUB-TRANS TIME CONST. | 0.005s | 0.0055s | 0.006s | 0.015s | 0.016s |
T’do | O.C. FIELD TIME CONST. | 0.4s | 0.45s | 0.55s | 0.57s | 0.59s |
Ta | ARMATURE TIME CONST. | 0.006s | 0.0065s | 0.007s | 0.01s | 0.0105s |
60Hz @ 440V | 184S1 | 184S2 | 184S3 | 184S4 | 184S5 | |
Kcc | SHORT CIRCUIT RATIO | 0.466 | 0.489 | 0.539 | 0.420 | 0.435 |
Xd | DIR. AXIS SYNCHRONOUS | 2.148 | 2.047 | 1.857 | 2.380 | 2.297 |
X’d | DIR. AXIS TRANSIENT | 0.217 | 0.199 | 0.190 | 0.181 | 0.175 |
X”d | DIR. AXIS SUBTRANSIENT | 0.137 | 0.140 | 0.119 | 0.099 | 0.095 |
Xq | QUAD. AXIS REACTANCE | 1.063 | 1.029 | 0.916 | 1.151 | 1.109 |
X”q | QUAD. AXIS SUBTRANSIENT | 0.24 | 0.234 | 0.202 | 0.201 | 0.194 |
X2 | NEGATIVE SEQUENCE | 0.194 | 0.187 | 0.179 | 0.151 | 0.145 |
X0 | ZERO SEQUENCE | 0.093 | 0.089 | 0.080 | 0.036 | 0.036 |
T’d | TRANSIENT TIME CONST. | 0.02s | 0.022s | 0.024s | 0.024s | 0.025s |
T”d | SUB-TRANS TIME CONST. | 0.005s | 0.0055s | 0.006s | 0.015s | 0.016s |
T’do | O.C. FIELD TIME CONST. | 0.40s | 0.45s | 0.55s | 0.57s | 0.59s |
Ta | ARMATURE TIME CONST. | 0.006s | 0.0065s | 0.007s | 0.010s | 0.0105s |
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developments, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.
OVERALL AND MOUNTING DIMENSIONS
Product detail pictures:
Related Product Guide:
abide by the contract", conforms to the market requirement, joins during the market competition by its superior quality also as provides extra comprehensive and exceptional service for consumers to let them turn into significant winner. The pursue of the business, is definitely the clients' gratification for China OEM 240v Ac Alternator - 18KW-32KW LTP184 Series Brushless AC Alternator Dynamo – Landtop , The product will supply to all over the world, such as: Mozambique, Mecca, Las Vegas, We put the product quality and customer's benefits to the first place. Our experienced salesmen supply prompt and efficient service. Quality control group make sure the best quality. We believe quality comes from detail. If you have demand, allow us to work together to get success.
By Edwina from Istanbul - 2017.06.25 12:48
The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
By Marcia from Montpellier - 2017.09.16 13:44