Call Us Now!

3KW-50KW STC Three Phase Brush Dynamo Alternator

Short Description:

Operating Condiyions:

Under the following environment, The generator could be continuous and rated running:

1.Above sea level: Not exceed 1000m

2.Cooling air temperature: 258~313K(-15 oC ~ 40 oC)

3.Relative air damping: not exceed 90%


Product Detail

Product Tags

STC THREE PHASE ALTERNATOR

Model

Rated Output  (KW)

Rated Capacity            (Kva)

Rated Current  (A)

Rated Speed (r/min)

Rated Voltage (V)

Frequency    (Hz)

N,W (kg)

G.W (kg)

Size(cm)

20″ PCS

STC-3

3

3.8

5.4

1500/1800

 

 

 

 

 

 

 

 

 

 

400/230

 

 

 

 

 

 

 

 

 

 

50/60

 

 

 

 

 

 

 

 

 

 

45

53

51*29*43

455

STC-5

5

6.3

9

70

80

61*34*50

279

STC-7.5/8

7.5/8

9.4

13.5

72

82

61*34*50

279

STC-10

10

12.5

18.1

89

103

65*39*54

211

STC-12

12

15

21.7

100

106

65*39*54

211

STC-15

15

18.8

27.1

135

146

70*42*58

170

STC-20

20

25

36.1

145

156

70*42*58

170

STC-24

24

30

43.3

147

165

70*42*58

170

STC-30

30

37.5

54.1

300

320

88*50*69

95

STC-40

40

50

72.2

345

365

88*50*69

95

STC-50

50

62.5

90.2

390

410

88*50*69

95

STC Three Phase Alternator Suppliers

This series generators are to be used in town, countryside, worksites, mountain and pasture as electric power source for lighting purpose, it can also he used as reserved power source for emergent case using.
The generators are of dripproof with rotary field type and adopt harmonic excitation system, easy operation and maintenance.
The generators are three-phase, four-wire type, adopting star connection with neutral point. The rated line voltage is 400V, phase voltage 230V, frequency 50Hz. power factor 0.8(lag). We can provide 60Hz and the other voltage’s generator according to the customer’s request.
They can be coupled with a prime mover directly or through v-belt making right or reverse continuous rotation at the rated speed. When the rotation speed of prime mover changs 3% or so and load varies in the range of 0~100% cos j 0.8~1.0, the generators offer constant voltage, when sudden change (increase or decrease) of load, the generator will soon return to their normal working state, at the same time, without any starting device the generator can directly start an unloaded squirrel cage induction motor.