◆The technical performance and mounting dimension of LTP series generators are
international IEC 60034,NEMA MG1-32,ISO8528,CSA C22.2-100,VDE0530 and
national GB755 standards compliant,the quality of prodcts can reach current international standard.
◆Excellent compatibility with drive systems:standard mounting dimensions can be coupled to any
diesel engines from worldwide,many S.A.E flanges and S.A.E drive discs can be easily interchangealble.
◆Easy access for installation and maintenance,including:coupling to engines,connecting for lead
wire,adjustment for AVR,connecting for rectifier,integrating with current transformers.For balanced
rotor with two sealed and quality ball bearing,LTP generators have the featues of little vibration and
low noise.
◆The standard enclosure protection is IP23.
◆And with standard permanent magnet generator excitation system(PMG)


Product Detail

Product Tags

50Hz – 1500rpm CLASS “H”         
RATING Winding 311/0.8 Power Factor Winding 05
Duty/Temp Rise/Ambient  T° Cont./125K/40°C Standby/150k/40°C Cont./125K/40°C
Phase 3 Phase 3 Phase 1 Phase
Voltage Y 380 400 415 400 380 400 415 400 220/230/240
220 230 240   220 230 240   Power Factor
YY       220       220 0.8 1
LTP164S1 KVA 8.1 8.1 8.1 8.1 8.8 8.8 8.8 8.8 6.5 6.5
KW 6.5 6.5 6.5 6.5 7 7 7 7 5.1 6.5
LTP164S2 KVA 11 11 11 11 11.9 11.9 11.9 11.9 8.8 8.8
KW 8.8 8.8 8.8 8.8 9.5 9.5 9.5 9.5 7 8.8
LTP164S3 KVA 13.5 13.5 13.5 13.5 14.8 14.8 14.8 14.8 10.8 10.8
KW 10.8 10.8 10.8 10.8 11.8 11.8 11.8 11.8 8.6 10.8
LTP164S4 KVA 16 16 16 16 17.5 17.5 17.5 17.5 12.8 12.8
KW 12.8 12.8 12.8 12.8 14 14 14 14 10.2 12.8

 

60Hz – 1800rpm CLASS “H”                  
RATING Winding 311/0.8 Power Factor Winding 05
Duty/Temp Rise/Ambient  T° Cont./125K/40°C Standby/150k/40°C Cont./125K/40°C
Phase 3 Phase 3 Phase 1 Phase
Voltage Y 380 400 415 400 380 400 415 400 220/230/240
220 230 240   220 230 240   Power Factor
YY       220       220 0.8 1
LTP164S1 KVA 9.8 9.8 9.8 9.8 10.5 10.5 10.5 10.5 7.8 7.8
KW 7.8 7.8 7.8 7.8 8.4 8.4 8.4 8.4 6.2 7.8
LTP164S2 KVA 13.2 13.2 13.2 13.2 14.3 14.3 14.3 14.3 10.6 10.6
KW 10.6 10.6 10.6 10.6 11.4 11.4 11.4 11.4 8.5 10.6
LTP164S3 KVA 16.2 16.2 16.2 16.2 17.7 17.7 17.7 17.7 13 13
KW 13 13 13 13 14.2 14.2 14.2 14.2 10.4 13
LTP164S4 KVA 19.2 19.2 19.2 19.2 21 21 21 21 15.4 15.4
KW 15.4 15.4 15.4 15.4 16.8 16.8 16.8 16.8 12.3 15.4

 

Frequency/R.P.M 50Hz-1500rpm 60Hz-1800rpm
Duty/Ambient T° Continuous/40°C Continuous/40°C
Ins.Class/ T° Rise H/125°  K H/125°  K
Load/Phase/P.F. Full load/3Phase/0.8 Full load/3Phase/0.8
Voltage Y 380 400 415 400 380 416 440 480
220 230 240   220 240 200  
YY       220   208   240
LTP164S1 η(%) 75.5 76.1 76.5 77 75 75.6 76.2 77.3
LTP164S2 η(%) 78.6 79.2 79.6 80 78.3 78.8 79.2 80.4
LTP164S3 η(%) 80 80.6 81 81.4 79.8 80.2 80.7 81.6
LTP164S4 η(%) 81 81.5 81.9 82.4 80.7 81.2 81.6 82.6

 

REACTANCE-TIME CONSTANT(s) H CLASS
  50Hz @ 400V LTP164S1 LTP164S2 LTP164S3 LTP164S4
Kcc SHORT CIRCUIT RATIO 0.556 0.563 0.570 0.577
Xd DIR. AXIS SYNCHRONOUS 1.8 1.777 1.754 1.734
X’d DIR. AXIS TRANSIENT 0.184 0.181 0.179 0.177
X”d DIR. AXIS SUBTRANSIENT 0.115 0.113 0.112 0.111
Xq QUAD. AXIS REACTANCE 0.895 0.883 0.872 0.861
X”q QUAD. AXIS SUBTRANSIENT 0.207 0.203 0.201 0.199
X2 NEGATIVE SEQUENCE 0.172 0.17 0.168 0.166
X0 ZERO SEQUENCE 0.078 0.077 0.076 0.075
T’d TRANSIENT TIME CONST. 0.012 s 0.014 s 0.016 s 0.018 s
T”d SUB-TRANS TIME CONST. 0.003 s 0.0035 s 0.004 s 0.0045 s
T’do O.C. FIELD TIME CONST. 0.2 s 0.25 s 0.3 s 0.35 s
Ta ARMATURE TIME CONST. 0.004 s 0.0045 s 0.005 s 0.0055 s

 

  60Hz @ 440V LTP164S1 LTP164S2 LTP164S3 LTP164S4
Kcc SHORT CIRCUIT RATIO 0.445 0.452 0.460 0.465
Xd DIR. AXIS SYNCHRONOUS 2.248 2.211 2.174 2.149
X’d DIR. AXIS TRANSIENT 0.23 0.225 0.223 0.219
X”d DIR. AXIS SUBTRANSIENT 0.144 0.14 0.139 0.138
Xq QUAD. AXIS REACTANCE 1.117 1.098 1.081 1.068
X”q QUAD. AXIS SUBTRANSIENT 0.258 0.252 0.249 0.246
X2 NEGATIVE SEQUENCE 0.215 0.212 0.208 0.206
X0 ZERO SEQUENCE 0.098 0.096 0.094 0.093
T’d TRANSIENT TIME CONST. 0.012 s 0.014 s 0.016 s 0.018 s
T”d SUB-TRANS TIME CONST. 0.003 s 0.0035 s 0.004 s 0.0045 s
T’do O.C. FIELD TIME CONST. 0.2 s 0.25 s 0.3 s 0.35 s
Ta ARMATURE TIME CONST. 0.004 s 0.0045 s 0.005 s 0.0055 s

 
Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developments, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.

1 (1)

2

1 (3)

1 (2)

Note: Products and materials shown in this catalogue may,at any time,be modified in order to follow the latest technological
developm-ents, improve the design or change the conditions of utilisation. Their description cannot in any case engage
LANDTOP liability.

OVERALL AND MOUNTING DIMENSIONS

02


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us